MODEL
SQFB
Kick-down, pilot operated, balanced piston sequence valve
SERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
Kick-down sequence valves will kick completely open and remain open once the pressure at the inlet (port 1)
exceeds the valve setting, creating an unrestricted flow path from port 1 to port 2 (sequence). The pressure setting
at port 1 is relative to the drain (port 3). The valve remains open as long as the pressure at port 1 exceeds the
pressure at port 2. To reset the valve, pressure at port 1 must fall below the setting of the valve, flow from port 1 to
port 2 must cease, and pressure at port 2 must be equal to or greater than the pressure at port 1.
TECHNICAL DATA
Factory Pressure Settings Established at Kick down point
Maximum Operating Pressure 350 bar
Response Time - Typical 25 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 50 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-202-007
Seal kit - Cartridge Polyurethane: 990-002-002
Seal kit - Cartridge Viton: 990-202-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
O Handknob with Panel Mount
(A)ADJUSTMENT RANGE
A 100 - 3000 psi (7 - 210 bar), 1000 psi
(70 bar) Standard Setting
B 50 - 1500 psi (3,5 - 105 bar), 1000 psi
(70 bar) Standard Setting
C 150 - 6000 psi (10,5 - 420 bar), 1000
psi (70 bar) Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 400 psi (28
bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200 psi (14
bar) Standard Setting
W 150 - 4500 psi (10,5 - 315 bar), 1000
psi (70 bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/
SQFB
TECHNICAL FEATURES
For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.
NOTES
Model Code Example: SQFBLANCONFIGURATION OPTIONS